HomeProduct SearchSite MapCheckoutTrack Your Order
PROGRAMMERS
Search by Keyword

Search by Keyword

Product Categories

Product Categories

Sort By:
MEP100MEP100"Programmer, Relight function, 10 sec PTFI. "
MEP100PProgrammer, Relight operation, 10 sec PTFI, 15 sec post purge.
MEP101Programmer, Relight function, allow flame signal until 60 seconds after interlock circuit closes.
MEP102Programmer, Non-recycle on flame fail, 5 second PTFI.
MEP103Programmer, Fixed 10 sec SISP*, 10 sec MTFI, re-try once on pilot failure, fixed 30 sec post purge. *Spark Igniter Sensing Period
MEP104Programmer, Non-recycle on flame fail, 10 second PTFI.
MEP105Programmer, Non-recycle on flame fail, lockout on air-flow open with flame present, 10 second PTFI.
MEP106Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.
MEP1075 sec purge, 10 second PTFI, 5 minute delay following flame failure. For natural draft atmospheric gas burners
MEP108Non-recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge, no FM Approval.
MEP109Programmer, Immediate ignition and pilot after limits are closed, 10 sec PTFI (fixed), 10 sec MTFI, intermittent pilot, non-recycle on flame fail.
MEP130Programmer, Relight operation, 30 sec PTFI, no agency approvals
MEP230Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start.
MEP230HProgrammer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization.
MEP235Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start, lockout on air flow open 10 seconds after the start of a cycle, selectable recycle/non-recycle lockout on air flow open after flame is proven, and dedicated lockout after loss of flame.
MEP236Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start with additional 6 second ignitor on time with main fuel. To be used with intermittent pilot only,
MEP238Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start. Ignition de-energized 3 seconds after pilot detected. Provides 8 second pilot stabilization period.
MEP290Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, prove open at start, and post purge (0 to 90 seconds).
MEP536Same as MEP236, 10 second trial for ignition, run-check switch, will not lockout on air flow open during purge.
MEP537Programmer, Selectable purge, PTFI, post purge, prove open at start, recycle/non-recycle (with one recycle on flame fail), 10 sec MTFI.
1 2
Payment Processing
Verisign
Credit Cards Accepted
Home  ·  Products  ·  About Us  ·  Contact Us  ·  Shipping  ·  Privacy Policy  ·  Sales and Refund Policy  ·  Links
Copyright © Industrial Equipment Company Houston, TX
sales@indeco-tx.com