MEP105Programmer, Non-recycle on flame fail, lockout on air-flow open with flame present, 10 second PTFI.
MEP106Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.
MEP1075 sec purge, 10 second PTFI, 5 minute delay following flame failure. For natural draft atmospheric gas burners
MEP108Non-recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge, no FM Approval.
MEP109Programmer, Immediate ignition and pilot after limits are closed, 10 sec PTFI (fixed), 10 sec MTFI, intermittent pilot, non-recycle on flame fail.
MEP130Programmer, Relight operation, 30 sec PTFI, no agency approvals
MEP230Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start.
MEP230HProgrammer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization.
MEP235Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start, lockout on air flow open 10 seconds after the start of a cycle, selectable recycle/non-recycle lockout on air flow open after flame is proven, and dedicated lockout after loss of flame.
MEP236Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start with additional 6 second ignitor on time with main fuel. To be used with intermittent pilot only,
MEP237Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start. Provides 0.30 second flame failure response time, for use with 85UVF flame scanner and MEDC2 amplifier.
MEP238Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start. Ignition de-energized 3 seconds after pilot detected. Provides 8 second pilot stabilization period.
MEP290Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, prove open at start, and post purge (0 to 90 seconds).
MEP300Programmer, relight operation on main flame fail, lockout on PTFI and MTFI flame fail, 10 sec PTFI (fixed), 5 sec pilot proving, 5 sec MTFI.
MEP304Programmer, 5 sec purge, 10 sec PTFI (fixed), 5 sec pilot proving, 10 sec MTFI, interrupted pilot, interrupted ignition, non-recycle on flame fail.
MEP397Programmer, 15 sec purge, provides interrupted ignition, interrupted pilot, non re-cycle on flame fail.
MEP536Same as MEP236, 10 second trial for ignition, run-check switch, will not lockout on air flow open during purge.
MEP537Programmer, Selectable purge, PTFI, post purge, prove open at start, recycle/non-recycle (with one recycle on flame fail), 10 sec MTFI.
MEP560Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization, 10 sec main trial for ignition, run-check switch.
MEP561Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge (30 sec max), prove open at start, 10 sec main trial for ignition, run-check switch.